This page is to inform the customer that the following Librestream part numbers:

  • MCD2500-N02, device part number 200416-02
  • MCD2500-N06, device part number 200155-02
  • MCD2500-N07, device part number 200416-02

have been certified to meet the following ratings with special conditions for safe use:

IECEx FME 08.0008X
Ex ic nA IIC T5 Gc
Ta = -10℃ to +40℃

FM08ATEX0077X
II 3G Ex ic nA IIC T5
Ta = -10℃ to +40℃

Special Condition of Use:

  • The I/O Cover shall be installed when the MCD2500-N is in a Hazardous Area.
  • The MCD2500-N shall not be used with the AC power adapter or I/O sled within the hazardous area.
  • The battery door shall be securely closed within the hazardous environment. Do not remove or install battery in the hazardous area.
  • Use only with an approved headset. Contact Librestream for more details.
  • Device meets EN 60079-0:2009, current standard is EN 60079-0:2012